TECHNICAL GUIDE
Configuring a WAVE ID® Serial (RS-232) Reader
Using the rf IDEAS® Configuration Utility
Step 1 — Download and Install
Download the rf IDEAS Configuration Utility from the Support > Product Downloads section of rfideas.com. Extract the ZIP file and run the installer on the Windows PC that will be connected to the RS-232 serial reader.
Step 2 — Connect the Reader
|
2a |
Wire the DB9 connector Connect the reader's RS-232 DB9 connector to an available serial port on the workstation, or to a USB-to-serial adapter if no native serial port is present. |
|
2b |
Identify the COM port Open Windows Device Manager and expand Ports (COM & LPT). Note the COM port number assigned to the reader. Only one COM port application can own the port at a time — close any other software using that port before continuing. |
|
2c |
Launch the utility and select the port Start the rf IDEAS Configuration Utility. On the Connect tab, choose Serial (RS-232) as the connection type and select the matching COM port from the dropdown, then click Connect. |
Figure 1 — Connect tab with Serial (RS-232) selected and COM port chosen
Communication settings: Serial-based readers communicate at 9600 baud, no parity, 1 stop bit, echo off. USB CDC readers present as a virtual COM port and do not require the baud rate to be set.
Step 3 — Verify and Configure
|
3a |
Confirm connection status The Status field must read “Ok 0.” When the reader is idle it shows a steady red LED; presenting a valid credential turns the LED green and populates the Card Data field. |
|
3b |
Test and save Present a card to the reader and confirm the correct data appears in the Output Test area. Click Write/Save to commit the configuration to the reader, then disconnect and restart the utility to verify the settings persisted. Use Auto Focus button on bottom left of test area to view reader output for serial models |
Figure 2 — Home tab showing a successful read in the Output Test area
Serial Reader Pinout (DB9)
AK2 — PS/2 pass-thru: power taken from keyboard/mouse connector

AK5 — DB9 data with 5 Vdc power supplied on Pin 9

AK6 — DB9 data with 9 Vdc power supplied on Pin 9

AK7 — External 9 Vdc wall adapter via DC jack

TX (pin 2), RX (pin 3), and GND (pin 5) are common to all serial reader variants. Pin 9 carries power on certain models — check the variant in use before wiring: AK2 draws power from a PS/2 pass-thru instead of pin 9; AK5 and AK6 supply +5V and +9V respectively on pin 9; AK7 uses an external 9VDC adapter via a separate DC jack rather than pin 9.
Key Options
|
Setting |
Purpose |
|
Connection Type |
Selects USB, Serial (RS-232), or Ethernet as the communication path to the reader. |
|
Baud Rate |
9600 baud, no parity, 1 stop bit, echo off. Applies to true serial (RS-232) readers only — USB CDC readers use a virtual COM port and do not require this to be set. |
Troubleshooting
• Reader not detected: confirm no other COM port application is running, then re-check the COM port number in Device Manager.
• Garbled or missing card data: verify the port is set to 9600 baud, no parity, 1 stop bit, echo off (true serial readers only — not applicable to USB CDC readers).
For further assistance, contact rf IDEAS® support or visit www.rfideas.com.