Step 1: FIND and Connect to Device:
a. Use Lantronix “Deviceinstaller” to search for Modbus devices and Note the IP address. Please see this link for Device Installer:
https://www.rfideas.com/sites/default/files/2020-02/DeviceInstaller-4407-SA.zip
b. Use a web browser and go directly to the IP address of the device. Change any parameters desired:
Step 2: GET a MODBUS SCANNER:
a. Use “Shortbus Modbus Scanner” or equivalent
b. Set “connection” pulldown to TCP and load in TCP address from #1 above
c. Set “Read Function” to FC4 – Input Registers
d. Set “Result Format” to Unsigned Integer 16-bit (or any other preferred date format)
e. Set “Length To Read” to 19
f. Press Connect.
g. Present card.
Step 3: SET MODBUS INPUT REGISTERS
a. Input Register 1: Sequence number (auto increment with each card presented)
b. Input Register 2: LUID
c. Input Register 3: Bit count
d. Input Register 7-19: Card data
Step 4: SET MODBUS OUTPUT REGISTERS
a. Holding Register 1: LED Control
· bit 0 = red
· bit 1 = green
· both = yellow
b. Holding Register 2: BEEP Control
· 1 – single short beep
· 2 – two short beeps
· 3 – three short beeps
· 4 – four short beeps
· 5 – five short beeps
· 101 – single long beep
· 102 – two long beeps
Step 5: TEST.
See EXAMPLES:
HID PROX READ:
a. Card number printed on card is 05607
b. Shortbus read below:
· Register 19 is 5607 which is the card number
EXAMPLE: BEEP 3 short beeps
· Reconnect Shortbus with only 2 registers, reading the Holding registers in Integer format
· Double click data in register 2.
· Click check box “Use FC 5/6”.
· Type in 3 for 3 short beeps.
· Click on “Send Write